* AC Input Voltage Range: 100VAC ~ 240VAC, +/-10%, 47 to 63 Hz.
* INPUT CURRENT:8.0 A ( RMS ) FOR 115VAC /4.0 A ( RMS ) FOR 230VAC.
* Input Power Factor: The minimum power factor at full load shall be
0.98/115V 60 Hz and 0.95/230V 50 Hz.
* Inrush current: 35A MAX. FOR 115 VAC / 55A MAX. FOR 230 VAC.
* DC Output: 500W maximum
|
OUTPUT VOLTAGE |
OUTPUT CURRENT |
REGULATION |
OUTPUT |
|
MIN ( A ) |
MAX ( A ) |
LOAD |
LINE |
RIPPLE & NOISE
MAX. [ P-P ] |
|
+5V |
0.5 |
25 |
±% |
±% |
60mV |
|
+12V |
2 |
40 |
±% |
±% |
120mV |
|
-12V |
0 |
0.8 |
±% |
±% |
120mV |
|
+3.3V |
0.5 |
25 |
±% |
±% |
60mV |
|
+5VSB |
0.1 |
3.5 |
±% |
±% |
60mV |
1. Noise Test - Noise bandwidth is from DC to 20 MHz.
2. Ripple frequencies greater than 1MHz shall be attenuated by the measurement
System.
3. Add 0.1uF/10uF capacitor at output connector terminals for ripple and noise
measurements.
4. The combined total power from 5V & 3.3V shall not exceed 170W.