New Page 1
TC-800PL
AC
Input:
VOLTAGE:100~240V,
(Active PFC
/ Full Range)
FREQUENCY:47~63Hz
Power factor
correction:0.99
INPUT CURRENT:12A
INRUSH CURRENT:65A/125A
MAX For 115/230
DC
Output:
|
OUTPUT
VOLTAGE |
OUTPUT CURRENT |
REGULATION |
OUTPUT |
|
MIN(A) |
MAX(A) |
LOAD |
LINE |
RIPPLE & NOISE
MAX.[P-P] |
|
+5V |
0.2 |
30 |
±5% |
±1% |
60mV |
|
+12V1 |
2 |
15 |
±5% |
±1% |
120mV |
|
+12V2 |
0 |
15 |
±5% |
±1% |
120mV |
|
+12V3 |
0 |
15 |
±5% |
±1% |
120mV |
|
+12V4 |
0 |
15 |
±5% |
±1% |
120mV |
|
-5V |
0 |
0.8 |
±10% |
±1% |
120mV |
|
-12V |
0 |
1 |
±10% |
±1% |
120mV |
|
+3.3V |
0.5 |
30 |
±5% |
±1% |
60mV |
|
+5VSB |
0 |
3 |
±5% |
±1% |
60mV |
The combined output power +5V&+3.3V shall not exceed 60A
The combined output power +5V&+12V&+3.3V maximum output 780W
The total power shall not exceed 800W.
Features…
l
Temperature
range:Operation
0°C~50°C
l
Hold
up time:16ms
at maximum load & normal input voltage
l
Efficiency:70%
Typical(Normal
Line)
l
Power
good signal:Should
be asserted high to indicate that+5VDC and
+3.3VDC
output are above the low voltage thresholds. Compatible signal
out with
100ms to 500ms.
l
Over
power protection:The
power supply shall shout down output
power exceeds 130% to 160%
l
Over
voltage protection:Standard
on +5V, set
at
6.25VDC±0.75VDC
l
Short
circuit protection:A
short circuit placed between the DC return
and the
output shall cause no damage and the power supply shall
shutdown.
l
EMI:FCC
part 15, subpart B, Class B, EN55022 CISPR22 Class B.
l
Meet EN-61000-3-2 CLASS D ( Active PFC )
l
Agency
approvals:UL60950,
CAN/CSA22.2 No.60950, TUV(IEC60950)
l
Remote On/Off control: when ps-on is pulled to TTL low. The DC output is
to be
Enabled, When ps-on is pulled to TTL high.
The
DC output is to
disabled
l
Cooling:By
forced air
2 x
80mm Fan
l
Connectors:24pin
+ 8 Pin + 4Pin + 10 x 12v Molex 4Pin + 2 x FDD 4 pin + 2 x SATA + 4 x PCI-E 6pin
l
Dimension:D220
x W150 x H86mm